常用銅導(dǎo)線(BVR)載流量對照表_第1頁
常用銅導(dǎo)線(BVR)載流量對照表_第2頁
常用銅導(dǎo)線(BVR)載流量對照表_第3頁
全文預(yù)覽已結(jié)束

下載本文檔

版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進(jìn)行舉報或認(rèn)領(lǐng)

文檔簡介

1、常用銅導(dǎo)線的選用常用銅導(dǎo)線(BVR)載流量對照表序號銅導(dǎo)線截面(mm)導(dǎo)線額定載流量(A)說明備注1035PLC信號見圖示要求205PLC信號見圖示要求30756PLC信號線、電源線見圖示要求4108PLC信號線、電源線見圖示要求51512電器控制二級回路布線強制性要求62516電器一次回路最小布線,電流互感器至電流表布線強制性要求74020從主母排取火的最小布線強制性要求86032電器一次回路布線按圖樣要求910040電器一次回路布線按圖樣要求1016063電器一次回路布線按圖樣要求1125080電器一次回路布線按圖樣要求12350100電器一次回路布線按圖樣要求13500125電器一次回路

2、布線按圖樣要求14700160電器一次回路布線按圖樣要求15950200電器一次回路布線按圖樣要求161200250電器一次回路布線按圖樣要求171500280電器一次回路布線按圖樣要求181850315電器一次回路布線按圖樣要求192400400電器一次回路布線按圖樣要求常用電線及電纜(電壓、電流、溫度)數(shù)據(jù)表序號銅電線型號單心載流量(25。C)(A)電壓降mv/M品字型電壓降mv/M緊挨一字型電壓降mv/M間距一字型電壓降mv/M兩心載流量(25。C)(A)電壓降mv/M三心載流量(25。C)(A)電壓降mv/M四心載流量(25。C(A)電壓降mv/M0.950.850.7 VV

3、YJVVVYJVVVYJVVVYJV11.5mm2/c202530.8626.7326.7326.731616131830.86131330.8622.5mm2/c283518.918.918.918.9233518.9182218.9183018.934mm2/c385011.7611.7611.7611.76343811.76233411.76284011.7646mm2/c48607.867.867.867.8640557.8632407.8635557.86510mm2/c65854.674.044.044.0555754.6745554.6748804.67616mm2/c90110

4、2.952.552.562.55701082.960752.665652.6725mm2/c1151501.871.621.621.631001401.9801001.6861051.6835mm2/c1451801.351.171.171.191251751.31051301.21081301.2950mm2/c1702301.010.870.880.914521011301600.871381650.871070mm2/c2202850.710.610.620.651902650.71652100.611752100.611195mm2/c2603500.520.450.450.52303

5、300.522002600.452202600.4512120mm2/c3004100.430.370.380.422704100.422353000.362553000.3613150mm2/c3504800.360.320.330.373104700.352753500.33403600.314185mm2/c4105400.30.260.280.333605700.293204100.254004150.2515240mm2/c4806400.250.220.240.294306500.243904850.214704950.2116300mm2/c5607400.220.20.210.

6、285007000.214505600.195005800.1917400mm2/c6508800.20.170.20.266008200.19      18500mm2/c75010000.190.160.180.25      19630mm2/c88011000.180.150.170.25       20800mm2/c110013000.170.150.170.24  &#

7、160;    211000mm2/c130014000.160.140.160.24序號銅電線型號單心載流量(25。C)(A)電壓降mv/M品字型電壓降mv/M緊挨一字型電壓降mv/M間距一字型電壓降mv/M兩心載流量(25。C)(A)電壓降mv/M三心載流量(25。C)(A)電壓降mv/M四心載流量(25。C(A)電壓降mv/M0.950.850.7 VV22YJV22VV22YJV22VV22YJV22VV22YJV2211.5mm2/c202530.8626.7326.7326.731616131830.86131330.8622.5m

8、m2/c283518.918.918.918.9233518.9182218.9183018.934mm2/c385011.7611.7611.7611.76294511.76243211.76253211.7646mm2/c48607.867.867.867.8638587.8632417.8633427.86510mm2/c65854.674.044.044.0553824.6745554.6747564.67616mm2/c881102.952.552.562.55721112.961752.665802.6725mm2/c1131571.871.621.621.63971451.985

9、1051.6861081.6835mm2/c1421921.351.171.171.191201801.31051301.21081301.2950mm2/c1712321.010.870.880.914022011241550.871371650.871070mm2/c2182940.710.610.620.651802850.71602050.611762200.611195mm2/c2653550.520.450.450.52503500.522012480.452172650.4512120mm2/c3054100.430.370.380.422704250.422352920.362

10、533100.3613150mm2/c3554780.360.320.330.373104850.352753430.32903600.314185mm2/c4105500.30.260.280.333605800.293234000.253334150.2515240mm2/c4906600.250.220.240.294306500.243814800.214004950.2116300mm2/c5607500.220.20.210.285007000.214405400.194675800.1917400mm2/c6508800.20.170.20.266008200.19      18500mm2/c75010000.190.160.180.25      19630mm2/c88011000.180

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論