




版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡介
1、中天建設(shè)集團(tuán)第三建設(shè)公司編號(hào)名稱加氣混凝土砌塊施工標(biāo)準(zhǔn)做法版本試行版生效期加氣混凝土砌塊施工標(biāo)準(zhǔn)做法編制: 審核: 批準(zhǔn): 建筑工程砌體工程標(biāo)準(zhǔn)化做法(試行版)一 材料····································
2、··················································
3、····3二 砌體施工流程圖············································
4、183;·····························3三 砌體施工圖標(biāo)準(zhǔn)化··················
5、83;·················································
6、83;··4四 砌塊堆放與加工··············································
7、;····························4五 預(yù)制構(gòu)件集中加工····················
8、··················································
9、·5六 砂漿集中拌制···············································
10、83;·····························5七 砌體施工控制重點(diǎn)··················
11、3;·················································
12、3;··7八 砌體定位··············································
13、83;····································8九 構(gòu)造節(jié)點(diǎn)做法············
14、··················································
15、···············10十 實(shí)測實(shí)量與過程檢查·································
16、;··································141.材料要求 1.1砌體結(jié)構(gòu)工程所用的加氣砼塊建議采用精準(zhǔn)砌塊,砌塊尺寸偏差控制在2mm以內(nèi)。1.2砌塊、水泥、鋼筋、黃砂、外加劑等材料進(jìn)場后應(yīng)復(fù)驗(yàn),報(bào)告結(jié)果符合設(shè)計(jì)要求后方可使用,嚴(yán)禁
17、使用砂漿王、砂漿精等砂漿外加劑。施工時(shí)所用砌塊的齡期至少在一個(gè)月以上。1.3填充砌體材料: ±0.000標(biāo)高以下采用灰砂磚,±0.000標(biāo)高以上采用加氣混凝土砌塊。加氣塊墻體底部200范圍內(nèi)及頂磚采用水泥磚或灰砂磚砌筑。2、砌體施工流程圖圖紙深化設(shè)計(jì)、工人交底加工車間設(shè)置、加工定位放線、砂漿拌制驗(yàn) 線張貼排磚圖、工人交底墻體砌筑、二次結(jié)構(gòu)設(shè)置檢 查頂部斜磚補(bǔ)砌驗(yàn) 收驗(yàn) 收3.砌體施工圖標(biāo)準(zhǔn)化3.1砌體施工前,項(xiàng)目部技術(shù)負(fù)責(zé)人應(yīng)組織相關(guān)人員進(jìn)行施工圖深化設(shè)計(jì),結(jié)合砌筑材料尺寸將工程所有墻體磚塊進(jìn)行CAD 排版,從而有效提高砌塊的使用率,同時(shí)也能提前發(fā)現(xiàn)一些施工問題,減少返工,
18、提高砌筑質(zhì)量。排版時(shí)應(yīng)遵循兩邊對(duì)稱,小砌塊為普通砌塊長度的1/3以上的原則,墻底必須設(shè)置三皮以上水泥磚,設(shè)計(jì)墻頂加氣塊高度應(yīng)大于普通砌塊長度的1/2以上,特別對(duì)轉(zhuǎn)角墻、丁字墻、十字墻組砌方式在排磚圖中均應(yīng)詳細(xì)繪制。3.2砌筑前,項(xiàng)目部技術(shù)人員應(yīng)根據(jù)排磚圖對(duì)作業(yè)人員進(jìn)行現(xiàn)場交底,并且應(yīng)將排磚圖粘貼到現(xiàn)場相應(yīng)墻體旁,指導(dǎo)作業(yè)人員正確組砌。4.砌塊堆放、集中加工與運(yùn)輸4.1 砌塊堆放區(qū)應(yīng)設(shè)置定型化防雨棚和100高混凝土或模板墊臺(tái),防止雨水浸泡加氣混凝土砌塊。4.2通過排磚圖識(shí)別各堵墻體中非標(biāo)磚的尺寸和數(shù)量,形成統(tǒng)一的下料單,并在砌塊加工車間集中下料,統(tǒng)一配送,供作業(yè)面工人使用,既避免了操作工人現(xiàn)場砍
19、磚所帶來的材料浪費(fèi)和質(zhì)量缺陷,又提高了工人的施工效率。4.3切磚機(jī)建議采用切割大理石的機(jī)器進(jìn)行改裝。4.4加氣塊前用鋼筋焊制定型化車,便于運(yùn)輸加氣塊;安排專人對(duì)加氣塊進(jìn)行碼放,碼放高度不得超過1.2米,下墊兩根方木,便于用定型化車整體裝車。在人貨電梯內(nèi)堆放整齊,碼放不得超過7排。到達(dá)施工樓層后整體裝車,指定位置整體卸車。減少單塊搬運(yùn),集中輸送,可以提高搬運(yùn)效率和減少加氣塊破損。5.預(yù)制構(gòu)件集中加工5.1根據(jù)砌筑施工排磚圖,梳理、匯總砌體工程中各類過梁、門窗預(yù)埋塊、U 型預(yù)埋塊、空調(diào)洞預(yù)制塊等砼預(yù)制構(gòu)件的尺寸和數(shù)量,形成下料單。制作工具式預(yù)制塊模具,提前統(tǒng)一加工預(yù)制,為砌體施工的實(shí)施提供配合。6
20、.砂漿拌制6.1砂漿集中拌制6.1.1施工現(xiàn)場應(yīng)設(shè)置砂漿集中攪拌區(qū),配備計(jì)量設(shè)備,制作、張貼形象化配合比牌,將重量換算成容器計(jì)具,便于現(xiàn)場操作,由固定人員操作確保砌筑砂漿質(zhì)量。6.1.2砂漿集中拌制與集中供應(yīng)可以減少砂、石、水泥等撒漏,杜絕成品砂漿因攪拌過多使用不完而造成的浪費(fèi),并且可以降低施工現(xiàn)場粉塵和噪音,減少城市空氣污染。6.1.3自拌水泥砂漿攪拌時(shí)間不得小于2min,保溫砂漿攪拌時(shí)間不得小于3min;砌筑砂漿應(yīng)在3小時(shí)內(nèi)使用完畢,當(dāng)施工期間溫度超過30時(shí),必須在2小時(shí)內(nèi)使用完畢。6.1.4非承重砌體墻砂漿強(qiáng)度M5、M10、M10三個(gè)等級(jí)。6.1.5同一施工點(diǎn)的不同類別砂漿,嚴(yán)禁同一天施
21、工;同一攪拌機(jī)在同一天不得攪拌不同強(qiáng)度的砂漿。6.2商品砂漿拌制6.2.1為減少工地?fù)P塵,應(yīng)使用預(yù)拌砂漿。為確保砂漿質(zhì)量,拌制時(shí)應(yīng)嚴(yán)格按廠家配合比控制用水量。7.砌體施工控制重點(diǎn)構(gòu)造柱邊貼3mm厚雙面膠,防止漏漿。砌塊下口切60*60斜口,保證柱砼澆搗飽滿斜磚及預(yù)制混凝土三角300畚箕口砌體灰縫橫平豎直,不大于12180200構(gòu)造柱底部放腳,馬牙槎不超過300mm5000構(gòu)造柱構(gòu)造柱底皮磚7.1.1墻體皮數(shù)應(yīng)嚴(yán)格按排磚圖進(jìn)行施工,砌塊砌筑應(yīng)采用滿鋪滿擠法砌筑,揉擠密實(shí),上下皮錯(cuò)縫搭砌,搭砌長度一般為砌塊長度的1/2,不得小于1/3,也不應(yīng)小于200mm。7.1.2砌塊內(nèi)外墻墻體應(yīng)同時(shí)咬槎砌筑,
22、臨時(shí)間斷時(shí)可留成斜槎,不得留“馬牙槎”,斜槎水平投影長度不應(yīng)小于高度的2/3。7.1.3砌筑砂漿應(yīng)該隨拌隨用,混合砂漿必須在3小時(shí)內(nèi)用完,當(dāng)施工期間最高溫度超過30度時(shí),必須在2小時(shí)內(nèi)使用完畢。砂漿稠度按80100mm控制。7.1.4外墻腳手眼不得在寬度小于1m 的窗間墻、砌體門窗洞口兩側(cè)200mm 和轉(zhuǎn)角處450mm 范圍內(nèi)墻體部位設(shè)置;腳手眼補(bǔ)砌不得用干磚填塞,應(yīng)用細(xì)石混凝土填塞。7.1.5砌塊上墻砌筑時(shí)含水率宜小于20%,應(yīng)采取在砌筑時(shí)向砌筑面適量濕水的方式,嚴(yán)禁用水管向砌塊澆水。砌筑時(shí)必須保證所有的四個(gè)砌筑面濕水,吸水深度以表面8mm10mm為宜,砌筑前24h澆水,砌塊表面宜呈濕潤無明
23、水;砌體施工完畢后不得使用水管澆水養(yǎng)護(hù),應(yīng)采用噴霧頭噴水保養(yǎng)3天。7.2門窗洞口及水電預(yù)埋7.2.1門邊兩側(cè)上下200mm內(nèi)均應(yīng)設(shè)置水泥預(yù)制塊,中間水泥預(yù)制塊間距不得超過600mm;窗戶兩側(cè)上下200mm內(nèi)均應(yīng)設(shè)置水泥預(yù)制塊,中間水泥預(yù)制塊間距不得超過300mm。7.2.2在砌塊墻體上剔槽開孔時(shí),應(yīng)在砌筑砂漿強(qiáng)度達(dá)到設(shè)計(jì)強(qiáng)度80%以上時(shí)進(jìn)行,如有松動(dòng)必須及時(shí)進(jìn)行補(bǔ)強(qiáng)處理。切鋸砌塊或在墻體上鉆孔、鏤槽時(shí),應(yīng)采用專用工具,不得用斧子或瓦刀任意砍劈,也不得在墻體上橫向鏤槽。砌體墻上暗敷水電管線時(shí),開槽深度不宜超過墻厚的1/3。線盒固定時(shí)應(yīng)凸出墻面15mm,保證抹灰后與面層齊平;敷設(shè)管線后應(yīng)采用聚合物
24、水泥砂漿填實(shí),且宜比墻面微凹2mm,并粘貼耐堿玻纖網(wǎng)格布或鋼絲網(wǎng),網(wǎng)格布或鋼絲網(wǎng)寬度應(yīng)蓋過縫隙邊緣每邊不小于100mm。8.砌體定位8.1砌筑定位放線必須采用雙控線(定位線、控制線都要彈出),結(jié)構(gòu)墻體上彈出砌筑定位線;根據(jù)結(jié)構(gòu)控制線放出墻體線,施工完成的砼墻面提前彈出結(jié)構(gòu)1m線。當(dāng)砌筑端頭無剪力墻,應(yīng)采用豎皮數(shù)桿;門洞口采用對(duì)角線表示,同時(shí)彈出門洞中線 ,對(duì)門窗、預(yù)留洞等特殊部位在墻體線上予以標(biāo)注,同時(shí)在作業(yè)前對(duì)班組予以交底,每間房間控制線相交處采用紅油漆標(biāo)識(shí)。墻體垂直控制線墻體抹灰控制線8.2在墻體砌筑時(shí),應(yīng)在墻體端部、轉(zhuǎn)角、構(gòu)造柱等陽角處設(shè)置垂直線控制墻體垂直度,在水平灰縫處應(yīng)隨砌體高度設(shè)
25、置控制灰縫水平。8.3砌筑前,利用激光掃平儀將地面門洞定位線彈到梁側(cè),將建筑1m線傳遞到梁側(cè)控制門洞標(biāo)高通過標(biāo)高線控制標(biāo)高雙控先引上墻控制左右位置8.4管道井、煙道也須設(shè)置雙控線。成品煙道和水電預(yù)留孔,在結(jié)構(gòu)施工階段,須放線定位。8.5將建筑控制線翻到砌體墻上,利用建筑1m線對(duì)水電預(yù)埋進(jìn)行精確定位。9.墻體構(gòu)造節(jié)點(diǎn)砌體示意圖9.1門剁與門窗過梁9.1.1與混凝土墻、柱相連的小于100mm的門剁和應(yīng)與混凝土墻、柱一起澆搗。9.1.2與梁相連的高度小于250mm的門過梁和應(yīng)與梁板一起澆搗,門窗過梁伸入墻內(nèi)大于300mm。9.2構(gòu)造柱9.2.1加氣塊砌體墻長大于5米、墻體交接及轉(zhuǎn)角、外墻陽角、長度大
26、于2.5米的獨(dú)立墻體的端部、洞口寬度大于2.0米的兩側(cè)均應(yīng)設(shè)置構(gòu)造柱 。9.2.2構(gòu)造柱與墻體連接處應(yīng)砌成馬牙槎,馬牙槎應(yīng)先退后進(jìn),馬牙槎凹入深度宜為60mm,每一組馬牙槎高度不應(yīng)超過300mm,馬牙槎下口應(yīng)切成60*60mm斜口,避免混凝土振搗不密實(shí)。構(gòu)造柱下口應(yīng)設(shè)置擠塑板,防止構(gòu)造柱砼澆搗后改變結(jié)構(gòu)梁受力結(jié)構(gòu)。9.2.3構(gòu)造柱模板應(yīng)在頂部斜磚完成3天后施工,安裝、加固時(shí),對(duì)拉螺桿嚴(yán)禁從砌體上穿過,防止構(gòu)造柱兩側(cè)砌體松動(dòng)、開裂,也嚴(yán)禁采用穿鐵絲的方式加固。9.2.4構(gòu)造柱下口鋼筋應(yīng)采用預(yù)埋方式設(shè)置,上口鋼筋采用植筋方式設(shè)置,植筋鋼筋深度應(yīng)大于13d,并且應(yīng)做好鋼筋拉拔試驗(yàn);在鋼筋綁扎時(shí)搭接區(qū)
27、域箍筋應(yīng)加密設(shè)置。9.4混凝土反坎9.3.1有防水要求的廚房、衛(wèi)生間、陽臺(tái)、管道、煙道、上人或非上人屋面等部位周邊墻體底部均應(yīng)設(shè)置混凝土反坎。9.3.2混凝土反坎在支模前應(yīng)進(jìn)行鑿毛處理,提高混凝土凝結(jié)力,反坎高度不得小于200mm,混凝土強(qiáng)度不得低于C20。9.4墻體拉墻筋9.4.1根據(jù)砌體排版圖劃分皮數(shù),沿墻高600mm(二層砌塊)墻體厚度大于200設(shè)置26拉結(jié)筋,墻體厚度為100時(shí)設(shè)置16拉結(jié)筋。拉結(jié)筋伸入墻體不宜小于1m,端部彎鉤為15d。拉結(jié)筋采取結(jié)構(gòu)預(yù)埋或后植筋方式設(shè)置,埋植深度不得低于60mm。9.5墻梁門過梁與墻過梁一起設(shè)置 外窗梁防水構(gòu)造9.5.1墻高度超出3米時(shí),在墻高中部設(shè)
28、置與墻柱連接的通長鋼筋水平墻梁,盡量與門窗過梁拉通;墻梁應(yīng)與墻同寬,高度200mm,梁筋應(yīng)采取結(jié)構(gòu)預(yù)埋或后植筋方式設(shè)置,埋植深度不得低于150mm。9.5.2窗頂部位將過梁底面做成外低內(nèi)高斜面,為窗邊滲漏水設(shè)置一道結(jié)構(gòu)防水。9.5.3當(dāng)外墻留設(shè)窗洞時(shí),窗臺(tái)應(yīng)澆筑120mm 高鋼筋混凝土壓頂,伸入墻內(nèi)300mm;如窗邊墻短于1000時(shí),窗臺(tái)應(yīng)設(shè)置通長窗臺(tái)梁,窗臺(tái)壓頂須由里往外找坡,坡度10%。9.5.4當(dāng)外墻長大于3m時(shí),為了減少外圍墻體的開裂,可在墻體中部設(shè)置通長鋼筋,貫通設(shè)置,內(nèi)配28鋼筋。9.6飄窗9.6.1在飄窗和平窗的混凝土構(gòu)件施工時(shí)上口應(yīng)在裝窗框處抬高20mm,下口在裝窗框處壓低20,做到內(nèi)高外低,設(shè)置一道結(jié)構(gòu)防水,防止雨水滲漏。 9.7灰縫有窗外墻墻體構(gòu)造 無窗外墻墻體構(gòu)造9.7.1砌筑灰縫應(yīng)橫平豎直,砂漿飽滿;加氣砼砌體水平、豎向灰縫厚度均為15mm,有拉強(qiáng)筋的水平灰縫厚度為25mm。砌筑一塊磚鋪一次灰,每層砌塊均應(yīng)帶線砌
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 健康一生分享會(huì)活動(dòng)方案
- 健康包粽子活動(dòng)方案
- 健康宣講志愿活動(dòng)方案
- 健康換新活動(dòng)方案
- 健康活動(dòng)安全活動(dòng)方案
- 健康科普進(jìn)企業(yè)活動(dòng)方案
- 健康調(diào)查活動(dòng)方案
- 健康飲食展會(huì)活動(dòng)方案
- 健身會(huì)員派對(duì)活動(dòng)方案
- 健身巡游活動(dòng)方案
- GB/T 19249-2017反滲透水處理設(shè)備
- 化學(xué)制藥工藝學(xué)試題庫
- 傳染病院內(nèi)感染預(yù)防與控制共26張課件
- 灌腸操作評(píng)分標(biāo)準(zhǔn)
- 知識(shí)產(chǎn)權(quán)法完整版教學(xué)ppt課件全套教程
- 2019年盲樣考核方案匯總
- 部編《小馬過河》完美課件1
- 天醫(yī)門符法修煉與祝由移病法
- 粒子加速器控制系統(tǒng)課件1-概述課件
- 義務(wù)教育科學(xué)課程標(biāo)準(zhǔn)(2022年版)
- 美國CLIA88質(zhì)量要求
評(píng)論
0/150
提交評(píng)論