




版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡(jiǎn)介
1、戶外斷路器、負(fù)荷開關(guān)試驗(yàn) 作 業(yè)指 導(dǎo)書303編碼:DQSY-04目次1適用范圍 ···········································&
2、#183;····································· 2892編寫依據(jù) ··········
3、83;·················································
4、83;···················· 2893作業(yè)流程圖····························
5、;··················································
6、;·· 2894安全風(fēng)險(xiǎn)辨析與預(yù)控·············································
7、83;······················ 2905作業(yè)準(zhǔn)備 ··························
8、;··················································
9、;······· 136作業(yè)方法 ·········································
10、183;··········································· 67質(zhì)量控制措施及檢驗(yàn)標(biāo)準(zhǔn)····
11、··················································
12、············ 91適用范圍1.1電壓等級(jí)35kV 及以下配網(wǎng)工程。1.2電氣類別適用于 10kV 配網(wǎng)工程戶外斷路器、負(fù)荷開關(guān)交接試驗(yàn)。2編寫依據(jù)表 2編寫依據(jù)序號(hào)引用資料名稱1GB 501502006電氣裝置安裝工程 電氣設(shè)備交接試驗(yàn)標(biāo)準(zhǔn)2DL 5601995電業(yè)安全工作規(guī)程(高壓試驗(yàn)室部分)3DL 5009.31997電力建設(shè)安全工作規(guī)程(變電所部分)4DL 4081991電業(yè)安全工作規(guī)程(發(fā)電廠和變電所電氣部分)5DL/T 51612002電氣裝置安裝工程
13、質(zhì)量檢驗(yàn)及評(píng)定規(guī)程6中國(guó)南方電網(wǎng)有限責(zé)任公司基建工程質(zhì)量控制作業(yè)標(biāo)準(zhǔn)(WHS)3作業(yè)流程圖4安全風(fēng)險(xiǎn)辨析與預(yù)控圖 3作業(yè)流程圖4.1戶外斷路器、負(fù)荷開關(guān)試驗(yàn)作業(yè)前,施工項(xiàng)目部根據(jù)該項(xiàng)目作業(yè)任務(wù)、施工條件,參照電網(wǎng) 建設(shè)施工安全基準(zhǔn)風(fēng)險(xiǎn)指南(下簡(jiǎn)稱指南)開展針對(duì)性安全風(fēng)險(xiǎn)評(píng)估工作,形成該任務(wù)的風(fēng)險(xiǎn)分析表。4.2按指南中與戶外斷路器、負(fù)荷開關(guān)試驗(yàn)作業(yè)相關(guān)聯(lián)的電網(wǎng)建設(shè)安全施工作業(yè)票(編碼: DQSY-04),結(jié)合現(xiàn)場(chǎng)實(shí)際情況進(jìn)行差異化分析,確定風(fēng)險(xiǎn)等級(jí),現(xiàn)場(chǎng)技術(shù)員填寫安全施工作業(yè)票,安全 員審核,施工負(fù)責(zé)人簽發(fā)。4.3施工負(fù)責(zé)人核對(duì)風(fēng)險(xiǎn)控制措施,并在日站班會(huì)上對(duì)全體作業(yè)人員進(jìn)行安全交底,接受交底的作
14、業(yè)人員負(fù)責(zé)將安全措施落實(shí)到各作業(yè)任務(wù)和步驟中。4.4安全施工作業(yè)票由施工負(fù)責(zé)人現(xiàn)場(chǎng)持有,工作內(nèi)容、地點(diǎn)不變時(shí)可連續(xù)使用 10 天,超過 10 天須 重新辦理作業(yè)票,在工作完成后上交項(xiàng)目部保存?zhèn)洳?。?4.1 作 業(yè)任 務(wù) 安 全 基準(zhǔn)風(fēng) 險(xiǎn) 指南序號(hào)危 害 名 稱風(fēng)險(xiǎn)種類風(fēng)險(xiǎn)等級(jí)風(fēng)險(xiǎn)控制措施1高處作業(yè)沒有正確使用 安全帶墜落中等風(fēng)險(xiǎn)高處作業(yè)必須正確使用安全帶2不規(guī)范使用梯子墜落低風(fēng)險(xiǎn)1. 使用合格梯子;2. 正確使用梯子;3. 必要時(shí)設(shè)專人扶梯3使用破損的試驗(yàn)設(shè)備進(jìn)行試驗(yàn)作業(yè)觸電中等風(fēng)險(xiǎn)1. 使用合格的設(shè)備;2. 試驗(yàn)前對(duì)設(shè)備進(jìn)行自檢;3. 設(shè)備外殼必須可靠接地;4. 試驗(yàn)時(shí)人員及設(shè)備應(yīng)在絕緣
15、墊上4高壓試驗(yàn)區(qū)域隔離警示 措施不足觸電中等風(fēng)險(xiǎn)高壓試驗(yàn)區(qū)域應(yīng)做好隔離措施,向外懸掛警示牌,設(shè)專人監(jiān)護(hù)5對(duì)被試品放電不戴絕緣手套,不使用放電棒觸電中等風(fēng)險(xiǎn)戴絕緣手套用放電棒對(duì)被試品放電6高壓試驗(yàn)時(shí),人員與設(shè) 備未滿足安全距離觸電 灼(燙)傷中等風(fēng)險(xiǎn)1. 試驗(yàn)人員試驗(yàn)開始前進(jìn)行現(xiàn)場(chǎng)巡查清理,確定工作范圍人員已處于安全區(qū)域;2. 試驗(yàn)過程中設(shè)專人監(jiān)護(hù),加壓前大聲并呼唱7試驗(yàn)接線錯(cuò)誤設(shè)備燒損低風(fēng)險(xiǎn)1. 試驗(yàn)人員熟悉試驗(yàn)規(guī)程及試驗(yàn)儀器的使用 方法;2. 試驗(yàn)前再次檢查接線是否正確8試驗(yàn)儀器操作錯(cuò)誤設(shè)備燒損低風(fēng)險(xiǎn)1. 試驗(yàn)人員熟悉試驗(yàn)規(guī)程及試驗(yàn)儀器的使用 方法,并按其要求操作;2. 試驗(yàn)時(shí)應(yīng)有人監(jiān)護(hù)并進(jìn)
16、行呼唱,操作人員應(yīng)站在絕緣墊上9未切斷試驗(yàn)電源更換接 線觸電中等風(fēng)險(xiǎn)試驗(yàn)電源應(yīng)有斷路開關(guān)和指示燈,更改接線時(shí) 或試驗(yàn)結(jié)束時(shí),應(yīng)首先斷開試驗(yàn)電源、放電并將 升壓設(shè)備高壓部分短路接地10升壓試驗(yàn)前,調(diào)壓器未調(diào)零設(shè)備燒損中等風(fēng)險(xiǎn)試驗(yàn)合閘前必須先檢查接線,通知現(xiàn)場(chǎng)人員遠(yuǎn) 離高壓試驗(yàn)區(qū)域,將調(diào)壓器調(diào)至零位緩慢上升, 注意設(shè)備動(dòng)態(tài)11絕緣電阻試驗(yàn)后未對(duì)被試設(shè)備進(jìn)行放電觸電中等風(fēng)險(xiǎn)試驗(yàn)后被試驗(yàn)設(shè)備必須放電12試驗(yàn)設(shè)備外殼無可靠接 地觸電中等風(fēng)險(xiǎn)試驗(yàn)設(shè)備外殼必須可靠接地,試驗(yàn)接地線應(yīng)符合規(guī)程規(guī)定13試驗(yàn)結(jié)束,未拆除試驗(yàn)線、遺留物品設(shè)備燒損中等風(fēng)險(xiǎn)試驗(yàn)完成應(yīng)對(duì)試驗(yàn)區(qū)域進(jìn)行檢查,做到“工完、 料凈、場(chǎng)清”,恢復(fù)試
17、驗(yàn)前狀態(tài)請(qǐng)您認(rèn)真檢查并簽名確認(rèn),您的簽名意味著將承擔(dān)相應(yīng)的安全質(zhì)量責(zé)任。施工單位檢查人: 監(jiān)理單位檢查人:日期: 日期: 注:對(duì)存在風(fēng)險(xiǎn)且控制措施完善填寫“”,存在風(fēng)險(xiǎn)而控制措施未完善填寫“×”,不存在風(fēng)險(xiǎn)則填寫“”,未檢查項(xiàng)空白。5作業(yè)準(zhǔn)備5. 1作業(yè)前施工條件表 5.1作業(yè) 前 施工 條件序號(hào)項(xiàng)目?jī)?nèi)容確認(rèn)人說明1任務(wù)單根據(jù)本單位實(shí)際設(shè)置內(nèi)容(包含本項(xiàng)工作)本工序施工負(fù)責(zé)人經(jīng)審批2圖紙?jiān)O(shè)備變更單、設(shè)計(jì)圖紙本工序施工負(fù)責(zé)人經(jīng)審批3預(yù)算材料表含主、輔材本工序施工負(fù)責(zé)人經(jīng)審批4施工方案施工措施、安全技術(shù)交底(項(xiàng)目部級(jí))本工序施工負(fù)責(zé)人經(jīng)審批5相關(guān)證照根據(jù)需要辦理涉及進(jìn)入工作場(chǎng)所的手續(xù)、證
18、件本工序施工負(fù)責(zé)人有效6確認(rèn)上一道 工序檢查合 格(1)斷路器、負(fù)荷開關(guān)已由倉(cāng)管簽收;檢查任務(wù)單、設(shè) 備更動(dòng)表、設(shè)計(jì)圖紙、施工方案、安全技術(shù)交底(項(xiàng)目部 級(jí))等工程項(xiàng)目的資料;包括斷路器、負(fù)荷開關(guān)型號(hào)、規(guī) 格、出廠合格證明書、出廠試驗(yàn)報(bào)告等廠家資料;(2)試驗(yàn)儀器對(duì)電源有規(guī)范要求,施工現(xiàn)場(chǎng)應(yīng)該具備試驗(yàn)電源本工序施工負(fù)責(zé)人合格5. 2人員、主要工器具及儀器儀表配置表 5.2人員、主要工器具及儀器儀表配置序號(hào)項(xiàng)目?jī)?nèi)容說明1人員配置施工階段建議工作人數(shù)現(xiàn)場(chǎng)施工負(fù)責(zé)人現(xiàn)場(chǎng)施工 質(zhì)安員技術(shù)崗位必須持有與作業(yè)工種 相應(yīng)的、有效的上崗證。輔助工 不得從事電氣設(shè)備試驗(yàn)等專業(yè)工 作布置及清理現(xiàn)場(chǎng)211設(shè)備測(cè)試2
19、2施工內(nèi)容 相對(duì)應(yīng)的 設(shè)備斷路器、負(fù)荷開關(guān)收集斷路器、負(fù)荷開關(guān)出廠合格證明文件及出廠試驗(yàn)報(bào)告3施工內(nèi)容 相對(duì)應(yīng)的 器具、機(jī)械 及工器具 儀表工器具:專用工具等。 儀器儀表:萬用表、試驗(yàn)變壓器、控制操作箱(調(diào)壓器)、 回路電阻測(cè)試儀、2500V 絕緣電阻表、溫濕度計(jì)、計(jì)算器等。 試驗(yàn)線材:電源線、專用試驗(yàn)線、接地線、放電棒等。 安全器具:安全警示帶、安全標(biāo)示牌、圍欄、絕緣手套、 絕緣墊等(1)根據(jù)現(xiàn)場(chǎng)情況使用的工具、儀器符合相關(guān)要求。(2)使用儀表有計(jì)量單位檢驗(yàn)合格證并在合格期間內(nèi)4完成開工 程序工作負(fù)責(zé)人向項(xiàng)目負(fù)責(zé)人報(bào)開工,由項(xiàng)目負(fù)責(zé)人向監(jiān)理單位完成開工報(bào)審手續(xù)施工準(zhǔn)備完成可報(bào)開工,當(dāng)施 工準(zhǔn)
20、備不足時(shí),上報(bào)該項(xiàng)目負(fù)責(zé) 人協(xié)調(diào)解決6作業(yè)方法表 6作業(yè)方法序號(hào)項(xiàng)目?jī)?nèi)容說明1作業(yè)前工作(1)現(xiàn)場(chǎng)施工負(fù)責(zé)人向進(jìn)入本施工范圍的所有工作人員明確交待本次施工設(shè)備狀態(tài)、作業(yè)內(nèi)容、作業(yè)范圍、進(jìn)度要求、2(1)斷路器、負(fù)荷開關(guān)的絕緣電阻;測(cè)量斷路器相間、相 對(duì)地的絕緣電阻;絕緣電阻值參照制造廠的規(guī)定,手動(dòng)絕緣 電阻表?yè)u到額定轉(zhuǎn)速才可接上被試設(shè)備,測(cè)量完畢,先切開 高壓線,然后停止搖動(dòng)絕緣電阻表(見圖 5-3-2)。圖 5-3-2 負(fù)荷開關(guān)絕緣電阻測(cè)量接線示圖(2)斷路器、負(fù)荷開關(guān)的交流耐壓試驗(yàn);試驗(yàn)前后應(yīng)測(cè)量 絕緣電阻,前后測(cè)量出的絕緣電阻值相比較不應(yīng)有明顯降低; 斷路器、負(fù)荷開關(guān)的交流耐壓試驗(yàn)在合閘
21、時(shí)相對(duì)地和分閘時(shí) 斷口間進(jìn)行;試驗(yàn)電壓應(yīng)按規(guī)程為 42kV。(3)測(cè)量絕緣電阻及交流耐壓試驗(yàn)的過程中,設(shè)專人監(jiān)護(hù), 禁止人員進(jìn)入測(cè)試范圍和觸碰斷路器、負(fù)荷開關(guān)及試驗(yàn)設(shè)備, 試驗(yàn)操作人員要注意儀表的指示情況以及斷路器、負(fù)荷開關(guān) 的狀況,如發(fā)現(xiàn)電壓變化幅度很大,電流急劇增加,斷路器、 負(fù)荷開關(guān)有異?,F(xiàn)象,應(yīng)立即降壓、切斷電源,停止試驗(yàn), 查明原因并處理后再進(jìn)行試驗(yàn) 3斷路器、負(fù)荷開關(guān)試驗(yàn)(4)在完成測(cè)量絕緣電阻及交流耐壓試驗(yàn)后,均需用放電棒對(duì)斷路器、負(fù)荷開關(guān)進(jìn)行放電(見圖 5-3-3)。圖 5-3-3 負(fù)荷開關(guān)交流耐壓試驗(yàn)接線示圖7試驗(yàn)過程 控制程序 記錄測(cè)試 數(shù)據(jù)試驗(yàn)數(shù)據(jù)與試驗(yàn)標(biāo)準(zhǔn)或者出廠試驗(yàn)報(bào)
22、告比較,分析判斷是 否合格現(xiàn)場(chǎng)校對(duì)測(cè)試數(shù)據(jù),如發(fā)現(xiàn)測(cè) 量數(shù)據(jù)不符合標(biāo)準(zhǔn)要求或者有疑 問的,應(yīng)分析原因;若試驗(yàn)方法、 試驗(yàn)設(shè)備、外部原因引起的,應(yīng) 排除;如屬設(shè)備缺陷,則填寫缺 陷通知書,報(bào)該項(xiàng)目負(fù)責(zé)人8清理現(xiàn)場(chǎng)拆出試驗(yàn)人員自裝的接地線、短路線、收拾儀器、儀表、 專用試驗(yàn)線、工具、圍欄、標(biāo)示牌等,不允許遺留物件在設(shè) 備上7質(zhì)量控制措施及檢驗(yàn)標(biāo)準(zhǔn)7.1 質(zhì)量控制措施 現(xiàn)場(chǎng)負(fù)責(zé)人應(yīng)根據(jù)現(xiàn)場(chǎng)情況安排技術(shù)人員負(fù)責(zé)質(zhì)量監(jiān)控。 作業(yè)人員必須熟悉工程作業(yè)流程和質(zhì)量檢驗(yàn)標(biāo)準(zhǔn);技術(shù)崗位人員必須持有與作業(yè)相應(yīng)、有效的上崗 證。 現(xiàn)場(chǎng)負(fù)責(zé)人在進(jìn)行安全技術(shù)交底時(shí)必須詳細(xì)介紹本作業(yè)質(zhì)量控制要點(diǎn)、常見的質(zhì)量通病及其防治措施
23、。 作業(yè)現(xiàn)場(chǎng)必須有經(jīng)審核批準(zhǔn)的設(shè)計(jì)圖紙和施工方案,作業(yè)人員必須按圖施工。 施工質(zhì)量檢驗(yàn)一般按以下方式進(jìn)行。質(zhì)量檢驗(yàn)一般采用三級(jí)檢驗(yàn)制,施工隊(duì)(組)對(duì)所施工的分項(xiàng) 工程應(yīng)進(jìn)行 100%的質(zhì)量自檢;項(xiàng)目部對(duì)所負(fù)責(zé)施工的分部工程和單位工程組織質(zhì)量檢查,復(fù)檢比例不宜 低于 50%;公司對(duì)單位工程組織檢查,抽檢比例不宜低于 20%。 隱蔽工程施工完成以及全部工序作業(yè)完成(轉(zhuǎn)序)時(shí),必須提前 24 小時(shí)通知監(jiān)理現(xiàn)場(chǎng)驗(yàn)收。7.2 質(zhì)量控制點(diǎn)表 7.2質(zhì)量控制點(diǎn)表單控制點(diǎn)控制方式WHS電氣試驗(yàn)7.3 檢驗(yàn)標(biāo)準(zhǔn)質(zhì)量檢驗(yàn)按10kV500kV 輸變電及配電工程質(zhì)量驗(yàn)收與評(píng)定標(biāo)準(zhǔn)第 8 冊(cè):配網(wǎng)工程中的 Q/CSG
24、表8-7.11 要求執(zhí)行。310附件 1安全施工作業(yè)票編碼:DQSY-04工作時(shí)間工作地點(diǎn)技術(shù)員現(xiàn)場(chǎng)安全員現(xiàn)場(chǎng)負(fù)責(zé)人安全風(fēng)險(xiǎn)分析及控制措施序號(hào)危害名稱風(fēng)險(xiǎn)種類風(fēng)險(xiǎn)等級(jí)風(fēng)險(xiǎn)控制措施1高處作業(yè)沒有正確 使用安全帶墜落 中等風(fēng)險(xiǎn)現(xiàn)場(chǎng)作業(yè)應(yīng)嚴(yán)格執(zhí)行相關(guān)安全規(guī)程及安全技術(shù)措施,并 重點(diǎn)關(guān)注但不限于以下措施: 高處作業(yè)必須正確使用安全帶。 使用合格梯子。 正確使用梯子。 必要時(shí)設(shè)專人扶梯。 使用合格的設(shè)備。 試驗(yàn)前對(duì)設(shè)備進(jìn)行自檢。 試驗(yàn)設(shè)備外殼必須可靠接地,試驗(yàn)接地線應(yīng)符合規(guī)程 規(guī)定。 試驗(yàn)時(shí)人員及設(shè)備應(yīng)在絕緣墊上。 高壓試驗(yàn)區(qū)域應(yīng)做好隔離措施,向外懸掛警示牌。 戴絕緣手套用放電棒對(duì)被試品放電。 試驗(yàn)人員試驗(yàn)開始前進(jìn)行現(xiàn)場(chǎng)巡查清理,確定工作范 圍人員已處于安
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 植樹減壓活動(dòng)方案
- 民警輔警春季活動(dòng)方案
- 法制宣教活動(dòng)方案
- 沈陽(yáng)帳篷節(jié)活動(dòng)方案
- 畢業(yè)郊游活動(dòng)方案
- 植樹活動(dòng)報(bào)到活動(dòng)方案
- 步行活動(dòng)策劃方案
- 油田掃雪活動(dòng)方案
- 河南商會(huì)活動(dòng)方案
- 桂溪開業(yè)活動(dòng)方案
- 中醫(yī)茶飲培訓(xùn)課件模板
- (湖北省高考卷)2024年湖北省普通高中學(xué)業(yè)水平選擇性考試高考物化生+政史地真題試卷及答案
- 康養(yǎng)醫(yī)養(yǎng)中心建設(shè)項(xiàng)目可行性研究報(bào)告
- 2024-2025學(xué)年人教PEP英語(yǔ)六年級(jí)下學(xué)期期末模擬試卷(含答案含聽力原文無音頻)
- T/CCBD 19-2022品牌餐廳評(píng)價(jià)規(guī)范
- GSK質(zhì)量管理體系介紹培訓(xùn)課件
- 學(xué)生宿舍改造設(shè)計(jì)方案
- 出國(guó)培訓(xùn)考試試題及答案
- 2025年中國(guó)樂器網(wǎng)數(shù)據(jù)監(jiān)測(cè)研究報(bào)告
- 西方文化導(dǎo)論試題及答案
- 2025-2030中國(guó)毛衣市場(chǎng)調(diào)研及重點(diǎn)企業(yè)投資評(píng)估規(guī)劃分析研究報(bào)告
評(píng)論
0/150
提交評(píng)論