




版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進行舉報或認(rèn)領(lǐng)
文檔簡介
1、Power Quality Assessment and Its Outlooks for Further ResearchXiao XiangningNorth China Electric Power University, ChinaSeptember 15, 10:40-11:10CICED2010, Nanjing, 12-16day;development of the power supply system for more intelligent3BackgroundZSmart Grid Research is becoming a focusing issue.Smart
2、Grid in China Can Achieve 10.5 Billion Tons of Carbon Emission Reduction over the Next Decade Strong Smart Gridin China4BackgroundsZAfter analyzing to the adverse impaction of SG, a n e x p e r t o f P Q standardization in USA, prof. McEachern said if the research work not to do on PQ problems same
3、times, smart grid will make power quality worse, not better. ZPower quality control should be regarded as a important part of smart grid .ZBut the benefits of SG are great, so it should c o n t i n u e 5BackgroundsZA power quality disturbance can be defined as a deviation from the ideal (sinusoidal,
4、 constant magnitude) voltage or current. ZBased on the monitored data or simulated data of power system operating parameters, power quality assessment, which is a very important part of power quality research area, is a process of calculating the quality indices and checking whether the values fulfi
5、ll the standard limitation, or whether the power disturbances make equipments miss-function. 6BackgroundsZThe power quality standards should be improved on the basis of further research, though a set of useful standards have been published. The changes of power load constitution, the development of
6、distributed generators, and the integration of large scale new sources, resulted from the construction of Smart Grid, will introduce challenges and opportunities for new sufficient important and interesting research in the domain of power quality. 7Extensive Voltage Sag Characteristics AssessedZVolt
7、age sags are, according to standards, characterized by one magnitude and one duration. Other indices are still in dispute.-IEC 61000-4-30, IEC61000-2-2(12,8), IEC61000-4-11(34)-IEEE std 493, IEEE std 1346 -CIGRE C 4.07-SEMI 47 -EN 50160-NRS 048 but there are many new indices are discussed and studie
8、d in8Extensive Voltage Sag Characteristics AssessedZFrom the view of influenced equipment, manufacturers, as well as power suppliers, should be aware of more characteristics than just magnitude and duration. 9Extensive Voltage Sag Characteristics AssessedZCIGRE/CIRED/UIE Joint Working Group C4.110 V
9、oltage Dip Immunity of Equipment and Installations(2010.04) For characterizing dip immunity of three-phase equipment, voltage-tolerance curves should be given for three general dip types: Type I, Type II and Type III dips.10Power quality economics-sagsZThe economic cost assessment of power quality a
10、nd the profit and loss analysis of power quality investment have contributed to the development of power quality industry and power quality economics.CIGRE JWG C4.107- Economic Framework for Voltage Quality-Propose a standardized method of collecting information, based on the experience of various i
11、nternational studies.-Recommend a methodology of using these data to cost and motivate power quality interventions on the power system or within the customer plant. - Provide indicative costs for specific industry sectors, where possible. -Provide detail the main factors influencing decisions about
12、the investment in increased immunity of equipment.ZVoltage sags are the most concerned voltage quality disturbances and Economics on sags is a critical study because the costs are very significant.11E.g. Cost of downtime is dependent on many factors. Voltage dip pattern with time of the day.varying
13、customer size in annual kWh consumptionvarying season and time of dayvarying business type12Corrected reliability indices based on economicsZBesides sustained interruptions, voltage sags and short-duration interruptions disturb the continuous operation of customers especially, of typical continuous
14、manufacturing plants.SAIDI the average interruption duration of the customers servedSASDI Average sag economic equivalent interruption duration /1min interruption costsiiCASDICS1(,) /isDiiENSASDICASDICSF V TTypeN13Example of a contour chart: HV/MV sites (CP95 value ) Customer Sag Frequency the numbe
15、r of sag events for the customer per yearCSF(Vs=80%,T=100ms,Type=Type III) =35 per yearType IType IIType IIIImmunity Curve14Corrected reliability indices based on economicsZThe definition of corrected reliability comprehensive index ASAI* (RS*) SAIDI and SASDI are coordinate of the economic losses o
16、f customers impacted by sustained interruptions, short-duration interruptions and voltage sags. *(1) 100%8760SAIDISASDIASAI-(1) 100%8760SAIDIASAI -15Voltage sag assessmentThe procedure for obtaining the corrected reliability indicesZMain four factors for assessmentDeal with Time AggregationDeal with
17、 Phase AggregationC a l c u l a t i o n o f Defined indices and check with the specified objectsProcedure16Voltage deviation assessmentZIEC 61000-4-30:2008IEC 61000-4-30 supports power quality measurement methods. The new edition 2008 cancels and replaces the first edition published in 2003. Measure
18、ment Aggregation The 10/12-cycle r.m.s. value shall be used. Underdeviation 200,.200,.200,if then if then rmsms idinrms under idinrmsms idinrms under irmsms iUUUUUUUU-200,200,200,if then if then rmsms idinrms over idinrmsms idinrms over irmsms iUUUUUUUU-150/180 cycle and 10 min aggregation are perfo
19、rmed using the square root of the arithmetic mean of the squared input values.2,1(/ )/100nunderdinrms under idiniUUUnU-2,1(/)/100noverrms over idindiniUUnUU-Overdeviation Underdeviation Overdeviation 17Voltage deviation assessmentZIEC-Assessment Indices suggested the number, or per cent, of values d
20、uring the measurement interval that exceed high or low contractual values might be counted; the worst-case values might be compared to high and/or low contractual values (the measurement interval might be different for this possibility); one or more 95 % (or other percentage) probability weekly valu
21、es, expressed in volts, might be compared to high and/or low contractual values; the number of consecutive values that exceed high and/or low contractual values might be counted. 18Voltage deviation assessmentZEuropean StandardsCENELEC EN 50160:2007 “Voltage characteristics of electricity supplied b
22、y public distribution systems”, 2007CLC/TR 50422 Application Guide to the European Standard EN 50160 on “Voltage Characteristics of Electricity Supplied by Public Distribution Systems”, 2003UNIPEDE Report “Application Guide to the European Standard EN 50160”, 1995UNIPEDE Report “Measurement Guide fo
23、r Voltage Characteristics”, 1995EURELEC “Power Quality in European Electricity Supply Networks” - 2nd edition, 200319Voltage deviation assessmentZA European Standards -Assessment Index during each period of one week, 95 % of the 10 min mean r.m.s. values of the supply voltage shall be within the ran
24、ge of 10 % of nominal voltage for LV and of declared supply voltage for MV . all 10 min mean r.m.s. values of the supply voltage shall be within the range of + 10 % / - 15 % (LV). 11non5%1008NNNN-20Voltage deviation assessmentZGB/T 12325-2008 the basic measurement time interval for supply voltage de
25、viation is a 10-cycle, and each 10-cycle measurement should be close to the next interval without overlapping; the arithmetic mean calculation is used over four optional aggregation intervals: 3s, 1min, 10min and 2h in accordance with local conditions and demands.GB/T 12325 also complements the term
26、 of qualified voltage rate(QVR). 1100%TQVRT21Voltage deviation assessmentZThe problem of two-side assessment with percentiles disturbance level x Compatibility level zLpdff(x)P(xzCP95)Assessed valuezCP95 disturbance level xpdfOverdeviation limitzL+f(x)UnderdeviationlimitzL-1.0(a)(b)how is 5% time/lo
27、cation statistical values picked out form two-side deviations to obtain the 95% compatibility level ?22Voltage deviation assessmentZIEC method the definitions of overdeviation and underdeviation are two independent parameters. Problem: if the CP95 value of voltage overdeviation complies with the lim
28、it level (or contractual agreement), in the 95% time of voltage positive deviation qualified, are all of the voltage r.m.s values qualified or do all of the voltage variations keep in the guarantee range? 23Voltage deviation assessmentZAn engineering method Respectively picking out 5% from the stati
29、stical spaces of underdeviation or overdeviation. Problem When the number of statistical data in one side of deviation is very small, which is always a common sense, one should be careful about the confidence interval . 24Voltage deviation assessmentZAssessment indexQualified rate, a core index, is
30、used as compatibility index between power systems and electric end-users. The worst-case values of deviations and the number of consecutive values that exceed high and/or low limits indicate a warning to system operators and power quality engineers. 25Voltage deviation assessmentZInteraction between
31、 DER (distributed generators / the integration of large scale new sources) and voltage deviation assessment DER impacts the time/spatial distribution of voltage magnitude. 26Voltage deviation assessmentZInteractionThe selection of index impacts the penetration rate of DER To determine how much DER c
32、an be accepted, a suitable performance indicator and an appropriate limit are needed.27OutlooksZIt is necessary to establish a standardized power quality assessment framework, to carry out power quality parameters and economic assessments, improving horizontal and vertical comparability of measured
33、or simulated data, in turns to promote the mitigation of power disturbances.ZWith the changes of load composition, we should research the characteristics of disturbances and the sensitive mechanism of the disturbed equipments, and improve the limitation and immunity standards ; 28OutlooksZWith the development of distributed generators and the integration of large scale new sources, it is significant to study the interaction between distribution network and DG on power quality and its assessment methods. 29Power frequencyFlickerVoltage sagswellUnba
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 詞義新解:高中英語語法知識點解析
- 我眼中的生活作文12篇
- 2025至2030中國壓板和安裝工具行業(yè)發(fā)展趨勢分析與未來投資戰(zhàn)略咨詢研究報告
- 敘事作文梅花的精神350字7篇
- 寫人作文這就是我650字12篇范文
- 勤奮好學(xué)講述一個學(xué)霸的成長故事6篇
- 期末考試前后的心理變化事件記敘作文11篇
- 童話寓言作文機智的猴子300字11篇范文
- 關(guān)節(jié)脫位的急救與護理講課件
- 新生兒產(chǎn)瘤與血腫的臨床鑒別
- 貴州省六盤水市2022-2023學(xué)年高二下學(xué)期期末教學(xué)質(zhì)量監(jiān)測英語試題(含答案)
- Spark大數(shù)據(jù)技術(shù)與應(yīng)用教學(xué)大綱
- 籃球場、羽毛球場項目施工方案
- 大型滑坡災(zāi)害的識別預(yù)警及應(yīng)急治理國家重點實驗室
- 鋼屋架安裝施工吊裝方案
- JJG 97-2001測角儀
- GB/T 4743-2009紡織品卷裝紗絞紗法線密度的測定
- GB/T 18971-2003旅游規(guī)劃通則
- 《雙眼視覺學(xué)》考試復(fù)習(xí)題庫(含答案)
- 2022更新國家開放大學(xué)電大【護理倫理學(xué)】形考任務(wù)2試題及答案
- 物業(yè)工程交接管理方案
評論
0/150
提交評論