



免費(fèi)預(yù)覽已結(jié)束,剩余1頁可下載查看
下載本文檔
版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡介
62271-203IEC:2003Common numbering of IEC 62271 publications falling under the responsibility of subcommittees SC 17A and SC. 17cIEC 62271 seriesHIGH-VOLTAGE SWITCHGEAR AND CONTROLGER高壓開關(guān)設(shè)備和控制設(shè)備Old IEC number if anypartNew title 1Common specifications 通用說明IEC 606942Seismic qualification for rated voltages of 72.5Kv and above72.5kV及以上設(shè)備抗地震性能-100High-voltage alternating current circuit-breakers 高壓交流斷路器IEC 60056101Synthetic testing 合成測試IEC 60427102High-voltage alternating current disconnections and earthing switches 高壓交流隔離開關(guān)和接地開關(guān) IEC 60129103Switches for rated voltages above 1kV and less than 52kV1kV52kV的開關(guān)設(shè)備IEC 60265-1104Switches for rated voltages of 52 kV and above52kV及以上的高壓開關(guān)設(shè)備IEC 60265-2105Alternating current switch-fuse combinations 高壓交流開關(guān)熔斷器組合IEC 60420106Alternating current contactors and contactor-based motor-starters交流接觸器和IEC 60470107Alternating current switchgear-fuse combinations高壓交流開關(guān)設(shè)備熔斷器組合-108Switchgear having combined function開關(guān)設(shè)備的聯(lián)動功能-109Series capacitor by-pass switches串連電容器-200AC metal-enclosed switchgear and control gear for rated voltage above 1kV and up to and including 52 kV1kV52 kV 交流金屬封閉開關(guān)和控制設(shè)備IEC 60298201Insulation-enclosed switchgear and controlgear for rated voltage up to and including 52 kV52 kV及以上絕緣封閉開關(guān)設(shè)備IEC 60466202High-voltage/ Low-voltage prefabricated substations 高低壓箱式變電站IEC 61330203Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV額定電壓在52 kV以上氣體絕緣金屬封閉開關(guān)設(shè)備 IEC 60517204High-voltage gas-insulated transmission lines for rated voltages of 72.5 kV and above額定電壓在72.5 kV及以上高壓氣體絕緣輸電線路IEC 61640(300)Guide for seismic qualification of high-voltage alternating current circuit-breakers高壓交流斷路器地震條件導(dǎo)則IEC 61166(301)Guide for inductive load switching感應(yīng)負(fù)載開關(guān)導(dǎo)則(高壓交流斷路器)IEC 61223(302)Guide for short-circuit and switching test procedures for metal-enclosed and dead tank circuit-breakers金屬封閉和落地罐式斷路器的短路和開合試驗(yàn)程序?qū)tIEC 61633(303)Use and handling of sulphur hexafluoride (SF6) in high-voltage switchgear and controlgear高壓開關(guān)和控制設(shè)備種SF6的使用和操作IEC 61634(304)Additional requirements for enclosed switchgear and controlgear from 1 kV to 72.5 kV to be used in severs climatic conditions 1 kV 到 72.5 kV封閉開關(guān)和控制設(shè)備用在特殊環(huán)境條件下的附加要求IEC 60932(305)Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV.52 kV及以上氣體絕緣金屬封閉開關(guān)設(shè)備的電纜連接IEC 60859(306)Direct connection between power transformers and gas-insulated metal-enclosed switchgear for rated voltages above 52 kV.52 kV及以上發(fā)電機(jī)變壓器和氣體絕緣金屬封閉開關(guān)設(shè)備的直接連接IEC 61639(307Use of electronic and associated technologies in auxiliary equipment of switchgear and controlgear開關(guān)設(shè)備和控制設(shè)備的輔助設(shè)備種電氣和相關(guān)技術(shù)的使用IEC 62063(308)Guide for asymmetrical short-circuit breaking test duty T 100a非對稱短路開端試驗(yàn)導(dǎo)則-(309)TRV parameters for high-voltage switchgear and controlgear for rated voltages above l kV and less than 100 kV.-(310)Electrical endurance testing for circuit-breakers rated 72.5 kV and above72.5 kV及以上的斷路器的電動力續(xù)性試驗(yàn)-62271-2003IEC:2003Table 102-Preferred rated insulation levels for rated voltages for equipment of range 1Rated voltage for equipmentUrkV (r.m.s.value)設(shè)備額定電壓Rated short-duration power-frequency withstand voltage(額定短時工頻耐受電壓)UdkV (r.m.s.value)Rated lightning impulse withstand voltage(額定雷電沖擊耐受電壓)UpkV(peckvalue)Phase-to-earth, across open switching device and between phase相對地,相間和通過斷開的設(shè)備Across the isolating distance通過的絕緣距離Phase-to-earth, across open switching device and between phase相對地,相間和通過斷開的設(shè)備Across the isolating distance通過的絕緣距離(1)(2)(3)(4)(5)72.514016032537510018521045052012323026555063014527531565075017032537575086024546053010501200NOTE Values in column(2) are applicableA) For type tests, phase-to-earth and between phases;B) For routine tests, phase-to-phase, and across the open switching device.Values in columns(3), (4) and (5) are applicable for type tests only.注意:第二列的電壓用于:(1) 相對地和相間的測試類型(2) 第三、四、五列種的電壓值僅適用于相對地,相間和通過斷開的開關(guān)設(shè)備的常規(guī)測試,62271-2003IEC:2003Table 103-Preferred rated insulation levels for rated voltages for equipment of range IIRated voltage for equipmentUrkV (r.m.s.value)設(shè)備額定電壓Rated short-duration power-frequency withstand voltage(額定短時工頻耐受電壓)UdkV (r.m.s.value)Rated switching impulse withstand voltage(額定開關(guān)沖擊耐受電壓)UskV (r.m.s.value)Rated lightning impulse withstand voltage(額定雷電沖擊耐受電壓)UpkV(peckvalue)Phase-to-earth, and between phase (note 3)相對地和相間across open switching device and /or isolating distance(note 3)Phase-to-earth, and across open switching device相對地和相間between phase(note 4)相間Across isolating distance (note 1,2 and 3)通過絕緣距離Phase-to-earth, and between phase相對地和相間across open switching device and /or isolating distance(note 3)通過斷開的開關(guān)設(shè)備和/或絕緣距離(1)(2)(3)(4)(5)(6)(7)(8)3004605958501275700(245)10501050(170)3625206759501425800(295)11751175(205)42065081510501575900(345)14251425(240)55071092511751760900(450)15501550(315)8009601270142524201100(650)21002100(453)NOTE 1 column (6) is also applicable to some circuit-breakers, see IEC 62271-100.NOTE 2 in column (6) , values in brackets are the peck values of the power-frequency voltage Ur/2/ 3 applied to the opposite terminal (combined voltage)In column (8), value in brackets are the peck values of the power-frequency voltage 0.7 Ur/2/ 3 applied to the opposite terminal (combined voltage).see annex D of IEC 60694.NOTE(3) Values in column(2) are applicable:(a) for type tests ,phase-to-earth and between phases;(b) for routine tests, phase-to-earth, phase-to-phase, and across the open switching device.Values in columns(3), (4), (5), (6), (7) and (8) are app
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 幼師上課評比活動方案
- 廣州親子志愿者活動方案
- 幼兒園體操大型活動方案
- 建材行業(yè)聯(lián)盟活動方案
- 幼兒計(jì)劃活動方案
- 建材公司砍價活動方案
- 廢紙紅包燈籠活動方案
- 幼兒美食開放日活動方案
- 幼兒基數(shù)活動方案
- 年貨購物活動方案
- 2023年廣東初中學(xué)業(yè)水平考試生物試卷真題(含答案)
- 監(jiān)理工作匯報(bào)-課件
- MIL-STD-1916抽樣標(biāo)準(zhǔn)簡介課件
- CSC-2000(V2) 變電站自動化監(jiān)控系統(tǒng)運(yùn)行手冊
- 鋼卷尺檢定證書
- 放到單位檔案的個人自傳
- 《湯姆˙索亞歷險記》整本書導(dǎo)讀課教學(xué)設(shè)計(jì)9篇
- 混凝土試件養(yǎng)護(hù)出入臺賬
- 鍋爐電梯井外彩鋼板封閉工程施工方案
- 中國科學(xué)院生態(tài)環(huán)境研究中心-環(huán)境工程A-927歷年真題2010-2015
- SCR脫硝反應(yīng)器尺寸修改后
評論
0/150
提交評論